Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.12666/435
Título : Passive exercise adaptation for ankle rehabilitation based on learning control framework
Autor : Abu Dakka, F.J.
Valera, A.
Escalera, J.A.
Abderrahim, M.
Page, A.
Mata, V.
Palabras clave : Ankle;Parallel Mechanism;Rehabilitation;Force control;Motion control;Parallel robots
Fecha de publicación : 1-sep-2020
Editorial : MDPI AG
DOI: 10.3390/s20216215
Versión del Editor: https://www.mdpi.com/1424-8220/20/21/6215
Citación : Sensors (Switzerland), 20 (21), art. no. 6215: pp. 1-23 (2020)
Resumen : Ankle injuries are among the most common injuries in sport and daily life. However, for their recovery, it is important for patients to perform rehabilitation exercises. These exercises are usually done with a therapist’s guidance to help strengthen the patient’s ankle joint and restore its range of motion. However, in order to share the load with therapists so that they can offer assistance to more patients, and to provide an efficient and safe way for patients to perform ankle rehabilitation exercises, we propose a framework that integrates learning techniques with a 3-PRS parallel robot, acting together as an ankle rehabilitation device. In this paper, we propose to use passive rehabilitation exercises for dorsiflexion/plantar flexion and inversion/eversion ankle movements. The therapist is needed in the first stage to design the exercise with the patient by teaching the robot intuitively through learning from demonstration. We then propose a learning control scheme based on dynamic movement primitives and iterative learning control, which takes the designed exercise trajectory as a demonstration (an input) together with the recorded forces in order to reproduce the exercise with the patient for a number of repetitions defined by the therapist. During the execution, our approach monitors the sensed forces and adapts the trajectory by adding the necessary offsets to the original trajectory to reduce its range without modifying the original trajectory and subsequently reducing the measured forces. After a predefined number of repetitions, the algorithm restores the range gradually, until the patient is able to perform the originally designed exercise. We validate the proposed framework with both real experiments and simulation using a Simulink model of the rehabilitation parallel robot that has been developed in our lab.
URI : http://hdl.handle.net/20.500.12666/435
Aparece en las colecciones: (Terrestre) Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
sensors-20-06215-v2 (1).pdf9,13 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons