Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/20.500.12666/531
Título : | Intercomparison of MAX-DOAS vertical profile retrieval algorithms: studies on field data from the CINDI-2 campaign |
Autor : | Tirpitz, J. L. Frieb, U. Hendrick, F. Alberti, C. Allaart, M. Apituley, A. Bais, A. Beirle, S. Berkhout, S. Bognar, K. Bösch, T. Bruchkouski, I. Cede, A. Lok Chan, K. Den Hoed, M. Donner, S. Drosoglou, T. Fayt, C. Friedrich, M. M. Frumau, A. Gast, L. Gielen, C. Gómez Martín, L. Hao, N. Hensen, A. Henzing, B. Hermans, C. Jin, J. Kreher, K. Kuhn, J. Lampel, J. Li, A. Liu, C. Liu, H. Ma, J. Merlaud, A. Peters, E. Pinardi, G. Piters, Ankie. Platt, U. Puentedura, O. Richter, A. Schmitt, S. Spinei, E. Stein Zweers, D. Strong, K. Swart, D. Tack, F. Tiefengraber, M. Van der Hoff, R. Van Roozendael, M. Vlemmix, T. Vonk, J. Wagner, T. Wang, Y. Wang, Z. Wenig, M. Wiegner, M. Wittrock, F. Xie, P. Xing, C. Xu, J. Yela González, M. Zhang, C. Zhao, X. |
Palabras clave : | MAX DOAS;Cindi 2 campaign |
Fecha de publicación : | 4-ene-2021 |
Editorial : | European Geoscience Union (EGU) |
DOI: | 10.5194/amt-14-1-2021 |
Versión del Editor: | https://amt.copernicus.org/articles/14/1/2021/ |
Citación : | Atmospheric Measurement Techniques 14: 1-35(2021) |
Resumen : | The second Cabauw Intercomparison of Nitrogen Dioxide measuring Instruments (CINDI-2) took place in Cabauw (the Netherlands) in September 2016 with the aim of assessing the consistency of multi-axis differential optical absorption spectroscopy (MAX-DOAS) measurements of tropospheric species (NO2, HCHO, O3, HONO, CHOCHO and O4). This was achieved through the coordinated operation of 36 spectrometers operated by 24 groups from all over the world, together with a wide range of supporting reference observations (in situ analysers, balloon sondes, lidars, long-path DOAS, direct-sun DOAS, Sun photometer and meteorological instruments). In the presented study, the retrieved CINDI-2 MAX-DOAS trace gas (NO2, HCHO) and aerosol vertical profiles of 15 participating groups using different inversion algorithms are compared and validated against the colocated supporting observations, with the focus on aerosol optical thicknesses (AOTs), trace gas vertical column densities (VCDs) and trace gas surface concentrations. The algorithms are based on three different techniques: six use the optimal estimation method, two use a parameterized approach and one algorithm relies on simplified radiative transport assumptions and analytical calculations. To assess the agreement among the inversion algorithms independent of inconsistencies in the trace gas slant column density acquisition, participants applied their inversion to a common set of slant columns. Further, important settings like the retrieval grid, profiles of O3, temperature and pressure as well as aerosol optical properties and a priori assumptions (for optimal estimation algorithms) have been prescribed to reduce possible sources of discrepancies. The profiling results were found to be in good qualitative agreement: most participants obtained the same features in the retrieved vertical trace gas and aerosol distributions; however, these are sometimes at different altitudes and of different magnitudes. Under clear-sky conditions, the root-mean-square differences (RMSDs) among the results of individual participants are in the range of 0.01–0.1 for AOTs, (1.5–15) ×1014molec.cm−2 for trace gas (NO2, HCHO) VCDs and (0.3–8)×1010molec.cm−3 for trace gas surface concentrations. These values compare to approximate average optical thicknesses of 0.3, trace gas vertical columns of 90×1014molec.cm−2 and trace gas surface concentrations of 11×1010molec.cm−3 observed over the campaign period. The discrepancies originate from differences in the applied techniques, the exact implementation of the algorithms and the user-defined settings that were not prescribed. For the comparison against supporting observations, the RMSDs increase to a range of 0.02–0.2 against AOTs from the Sun photometer, (11–55)×1014molec.cm−2 against trace gas VCDs from direct-sun DOAS observations and (0.8–9)×1010molec.cm−3 against surface concentrations from the long-path DOAS instrument. This increase in RMSDs is most likely caused by uncertainties in the supporting data, spatiotemporal mismatch among the observations and simplified assumptions particularly on aerosol optical properties made for the MAX-DOAS retrieval. As a side investigation, the comparison was repeated with the participants retrieving profiles from their own differential slant column densities (dSCDs) acquired during the campaign. In this case, the consistency among the participants degrades by about 30 % for AOTs, by 180 % (40 %) for HCHO (NO2) VCDs and by 90 % (20 %) for HCHO (NO2) surface concentrations. In former publications and also during this comparison study, it was found that MAX-DOAS vertically integrated aerosol extinction coefficient profiles systematically underestimate the AOT observed by the Sun photometer. For the first time, it is quantitatively shown that for optimal estimation algorithms this can be largely explained and compensated by considering biases arising from the reduced sensitivity of MAX-DOAS observations to higher altitudes and associated a priori assumptions. |
Descripción : | The supplement related to this article is available online at: https://doi.org/10.5194/amt-14-1-2021-supplement. |
URI : | http://hdl.handle.net/20.500.12666/531 |
E-ISSN : | 1867-8548 |
Aparece en las colecciones: | (CAB) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
amt-14-1-2021.pdf | 13,93 MB | Adobe PDF | Visualizar/Abrir | |
amt-14-1-2021-supplement.pdf | 25,13 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons