Examinando por Autor "Guerrero, H."
Mostrando 1 - 11 de 11
- Resultados por página
- Opciones de ordenación
Publicación Restringido A New Single-Sensor Magnetic Field Gradiometer(Igneta Connect, 2009-08-13) Lucas, I.; Díaz Michelena, Marina; De Manuel, V.; Plaza, J. A.; Duch, M.; Esteve, J.; Guerrero, H.In this work a magnetic field gradiometer device has been developed. This device is not composed by two sensors separated a certain distance but by a single-sensor device which measures the real gradient value just at the point where it is wanted to be measured. The experimental set-up consists of a sensor head (a membrane with a fixed permanent magnet on it) vibrating at its resonance frequency, due to an alternating magnetic field gradient. Detection is performed using an optoelectronic method. Two different measurement techniques have been used: frequency measurements (the resonance frequency is measured for every external magnetic field gradient value) and amplitude measurements (the signal amplitude is measured without changing the resonance frequency obtained without an external magnetic field gradient applied). The mechanical stresses of the membrane are related with the dependence of both magnitudes (frequency and amplitude) on the external magnetic field gradient. The minimum and maximum value of the resonance frequency and signal amplitude respectively, correspond with magnetic forces equal to the magnet weight of the sensor head. This prototype shows a noise-limited sensitivity of 2 Gauss/m/√Hz at zero gradient. This device could be used also as a magnetic susceptometer.Publicación Restringido A Sol–Gel based magneto-optical device for the NANOSAT space mission(Springer Link, 2009-03-31) Zayat, M.; Pardo, R.; Rosa, G.; Del Real, R. P.; Díaz Michelena, Marina; Arruego, Ignacio; Guerrero, H.; Levy, D.On December 2004, the Spanish Space Agency INTA (Instituto Nacional de Técnica Aeroespacial) launched the first nanosatellite called NANOSAT (Fig. 1) on board an European rocket Ariane 5, from the French Guyana. The satellite consists of a hexagonal device of <19 kg of weight with a diameter of about 50 cm, which describes a LEO orbit of 655 km of altitude. The main objective of the satellite is to probe the operation and performance of micro- and nanotechnologies in space environment. One of the scientific experiments implemented on board was the Sol–Gel based magnetic nanosensor.Publicación Restringido A study of the optical properties of photopolymer Fabry-Perot microcavities by a dual-wavelength fibre optic architecture(IOP Science Publishing, 2002-06-20) López Heredero, R.; Martín, S.; Fernández de Caleya, R. F.; Lobo Ribeiro, A. B.; Araújo, F. M.; Ferreira, L. A.; Santos, J. L.; Guerrero, H.; 0000-0002-7047-0273; 0000-0002-2988-1222; 0000-0003-2922-3489; 0000-0002-2197-8388; 0000-0002-0818-4268We present a novel method to study the behaviour of the optical properties of photopolymer materials with temperature. The photopolymer is deposited on the tip of optical fibres by dip coating to fabricate low-finesse Fabry-Perot microcavities. The signal processing technique utilized to interrogate the cavity is based on the generation of two quadrature phase-shifted interferometric signals using two Bragg fibre gratings. This technique enables the determination of the values of the thermo-optical coefficient and the linear coefficient of thermal expansion of the photopolymer. The effectiveness of the processing technique is also exploited in the study of the dependence of the temperature sensitivity on the cavity thickness.Publicación Restringido Comparative performance of static-mode ferrous MEMS gradiometers fabricated by a three-step DRIE process(IOP Science Publishing, 2010-05-21) Campanella, H.; Del Real, R. P.; Duch, M.; Guerrero, H.; Esteve, J.; Díaz Michelena, M.; Plaza, J. A.Two MEMS structures—a cantilever beam and a quad-beam—have been designed and fabricated through a three-step deep reactive ion etching (DRIE) process. Devices feature target patterns to align with an external optical detection system and a micromachined cavity to embed an NdFeB hard mini-magnet, thus releasing the stress of structures. Structures are intended for magnetostatic gradient measurements. Induced magnetic fields generate an attracting force on the magnet that deflects the sensor. Deflection is optically detected through nanometer-resolution confocal microscopy. The static-mode sensitivity of up to 1.86 × 10−4 T m−1 demonstrates that MEMS gradiometers are able to perform in situ gradiometry with a single sensor and miniaturized size. Suitable techniques for integrated detection are discussed.Publicación Restringido Dosimeter for The Two Towers in SEOSAT-INGENIO Based on the TMP36 Temperature Sensor(Institute of Electrical and Electronics Engineers, 2013-05-14) González Guerrero, M.; Jiménez Martín, Juan José; Hernando, Carlos; Álvarez, Maite; Guerrero, H.; Instituto Nacional de Técnica Aeroespacial (INTA)A dosimeter for space applications is presented. It is based on the ionization damage affecting the TMP36 sensors when they are exposed to external radiation, which produces an increase of their output voltages. This work explains the configuration, sensing mechanism and working modes of this device and reports the results obtained in a gamma radiation test carried out in March 2012. The test results allow us to select the mode of operation that provides the highest response to the TID, as well as the most sensitive devices. The highest sensitivity is above 100 μV/rad. This dosimeter is part of The Two Towers radiation monitor that will fly on board of the SEOSAT-INGENIO satellite.Publicación Restringido Focused-Ion-Beam-Assisted Magnet Fabrication and Manipulation for Magnetic Field Detection Applications(ACS Publications, 2009-02-16) Campanella, H.; Del Real, R. P.; Díaz Michelena, M.; Duch, M.; Guerrero, H.; Esteve, J.; Plaza, J. A.A focused-ion-beam-assisted technique intended for ultrasmall, hard-magnet fabrication has been developed. By means of ion-beam-induced milling and deposition, reduced-size NdFeB magnets were extracted from a macroscopic quarry and bonded to the surface of a thin-film bulk acoustic resonator (FBAR). Electrical characterization of the FBAR before and after bonding of the magnet was carried out, thus observing both a downshifting of the resonance frequency and a reduction of the quality factor of the resonator. The magnetic behavior of the nanomagnet has been confirmed by means of magnetometry measurements based on atomic force microscopy.Publicación Restringido Magnetic Technologies for Space: COTS Sensors for Flight Applications and Magnetic Testing Facilities for Payloads(Ingenta Connect, 2007-03-01) Díaz Michelena, M.; Del Real, R. P.; Guerrero, H.The increasing trend of using Commercial of the Shelf components for Aerospace Applications makes Space Agencies open a brand new testing line devoted to the up-screening and characterization in extreme conditions of these "underqualified" components. The up-screening needs to deal with the tasks of degassing, temperature testing and thermal shock, vibration, ageing and stressing, and irradiation of the component under test. In this paper we report on the up-screening process, the previous magnetic characterization and the in-flight resulting data obtained with the magnetic sensors of NANOSAT-01 mission, one and a half years after the launch. The up-screening of the magnetic sensors used in this mission succeed. Their final in-flight qualification is on the road as the behavior of the sensors is nominal.Publicación Restringido Micromachined low-finesse Fabry-Perot interferometer for the measurement of DC and AC electrical currents(Institute of Electrical and Electronics Engineers, 2003-04-22) López Heredero, Raquel; Santos, J. L.; Fernández de Caleya, R. F.; Guerrero, H.; López Heredero, R. [0000-0002-2197-8388]; Guerrero, H. [0000-0003-2922-3489]; Santos, J. L. [0000-0002-0818-4268]A micromachined low finesse Fabry-Perot interferometer for measuring DC and AC electrical current is presented. Interrogation of the microcavity is achieved by a dual-wavelength fiber Bragg grating technique working in quadrature. A linear relation between the DC electrical current and the optical phase defined by the microcavity was detected. Large enhancement of the sensitivity of the microcavities is presented with the use of a planar coil instead of a power line. The sensitivity of the sensor with the planar coil configuration is 7.9 rad/A and resolution of ∼0.18 mA//spl radic/Hz is achieved when the distance between the planar coil and the transducer head is 2 mm. The response of the sensor for AC measurements is 0.14 V/A with a resolution of 6 mA//spl radic/Hz when the distance between the power line and the transducer head is 5.5 cm.Ítem Restringido Micromachined low-finesse Fabry-Perot interferometer for the measurement of low DC electrical currents(Institute of Electrical and Electronics Engineers, 2002-05-10) López Heredero, Raquel; Santos, J. L.; Fernández de Caleya, R. F.; Araújo, F. M.; Ferreira, L. A.; Guerrero, H.; Guerrero, H. [0000-0003-2922-3489]; López Heredero, R. [0000-0002-2197-8388]An optical fiber current sensor based on a permanent magnet fixed on the center of a micromachined Si membrane has been presented. The transducing operation principle is magneto-mechanical and has a linear response. A great improvement of the sensitivity of the microcavities was achieved by the use of a planar coil. Interrogation of the transducer has been carried out using a Fabry-Perot interferometer with an all-fiber detection system to avoid the influence of electromagnetic noise. The effectiveness of a fiber scheme based on the utilization of two fibre Bragg gratings to generate two quadrature phase-shifted interferometric signals has also been reported.Publicación Acceso Abierto MOURA magnetometer for Mars MetNet Precursor Mission. Its potential for an in situ magnetic environment and surface characterization(Universidad Complutense de Madrid, 2016-10-14) Díaz Michelena, Marina; Sanz, Ruy; Belén Fernández, A.; De Manuel, V.; Cerdán, M. F.; Apéstigue, Víctor; Domínguez, J. A.; González Fernández, Luis Miguel ; Guerrero, H.; Dolores Sabau, M.; Kilian, R.; Baeza, O.; Ríos, F.; Herraiz, M.; Vázquez, L.; Tordesillas, J. M.; Covisa, P.; Aguado, J.; Ministerio de Economía y Competitividad (MINECO)El magnetómetro y gradiómetro MOURA forma parte de la instrumentación científica de la misión precursora de MetNet a Marte. En este trabajo se describen los objetivos de esta investigación, se recopilan las tareas de diseño y desarrollo del mismo así como su posterior calibración y se muestran las principales acciones de demostración emprendidas con el instrumento que muestran su capacidad para medidas magnéticas a bordo de aterrizadores y rovers. MOURA magnetometer and gradiometer is part of the scientific instrumentation for Mars MetNet Precursor mission. This work describes the objective of the investigation, summarizes the work done in the design and development of the sensor as well as its calibration, and shows the demonstration campaigns to show the potential of such instrument for planetary landers and roversPublicación Restringido Optical wireless links for intra-satellite communications: reflection models and hardware optimization(Aerospace Research Central, 2010-05-23) Tamayo, R.; Alonso, José; Jiménez Martín, Juan José; Arruego, Ignacio; Guerrero, H.; Instituto Nacional de Técnica Aeroespacial (INTA)The present work is a study on the propagation channel (physical layer) for wireless infrared communications in intra-satellite environments. Substituting cables and connectors with optical links inside a spaceborn platform offers many advantages and represents some technical challenges. We show analytical calculations, simulations, and experimental results for reflection models for aerospace materials, as well as wavelength division multiple access techniques for channel multiplexing. Improvements in the selection and optimization of emitter-detector pairs are also presented.










