Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12666/629
Title: Fundamental physics with ESPRESSO: Towards an accurate wavelength calibration for a precision test of the fine-structure constant
Authors: Schmidt, T. M.
Molaro, P.
Murphy, M. T.
Lovis, C.
Cupani, G.
Cristiani, S.
Pepe, F. A.
Rebolo, R.
Santos, N. C.
Abreu, M.
Adibekyan, V.
Alibert, Y.
Aliverti, M.
Allart, R.
Allende Prieto, C.
Alves, D.
Baldini, V.
Broeg, C.
Cabral, A.
Calderone, G.
Cirami, R.
Coelho, J.
Coretti, I.
D´Odorico, V.
Di Marcoantonio, P.
Ehrenreich, D.
Figueira, P.
Genoni, M.
Génova Santos, R.
González Hernández, J. I.
Kerber, F.
Londoni, M.
Leite, A. C. O.
Louis Lizon, J.
Lo Curto, G.
Manescau, A.
Martins, C. J. A. P.
Mégevand, D.
Mehner, A.
Micela, G.
Modigliani, A.
Monteiro, M.
Monteiro, M. J. P. F. G.
Mueller, E.
Nunes, N. J.
Oggioni, L.
Oliveira, A.
Pariani, G.
Pasquini, L.
Redaelli, E.
Riva, M.
Santos, P.
Sosnowska, D.
Sousa, S. G.
Sozzetti, A.
Suárez Mascareño, A.
Udry, S.
Zapatero Osorio, M. R.
Zerbi, Filippo M.
Keywords: Instrumentation: spectrographs;Techniques: spectroscopic;Cosmology: observations
Issue Date: 19-Feb-2021
Publisher: EDP Sciences
DOI: 10.1051/0004-6361/202039345
Published version: https://www.aanda.org/articles/aa/abs/2021/02/aa39345-20/aa39345-20.html
Citation: Astronomy and Astrophysics 646: A144(2021)
Abstract: Observations of metal absorption systems in the spectra of distant quasars allow one to constrain a possible variation of the fine-structure constant throughout the history of the Universe. Such a test poses utmost demands on the wavelength accuracy and previous studies were limited by systematics in the spectrograph wavelength calibration. A substantial advance in the field is therefore expected from the new ultra-stable high-resolution spectrograph ESPRESSO, which was recently installed at the VLT. In preparation of the fundamental physics related part of the ESPRESSO GTO program, we present a thorough assessment of the ESPRESSO wavelength accuracy and identify possible systematics at each of the different steps involved in the wavelength calibration process. Most importantly, we compare the default wavelength solution, which is based on the combination of Thorium-Argon arc lamp spectra and a Fabry-Pérot interferometer, to the fully independent calibration obtained from a laser frequency comb. We find wavelength-dependent discrepancies of up to 24 m s−1. This substantially exceeds the photon noise and highlights the presence of different sources of systematics, which we characterize in detail as part of this study. Nevertheless, our study demonstrates the outstanding accuracy of ESPRESSO with respect to previously used spectrographs and we show that constraints of a relative change of the fine-structure constant at the 10−6 level can be obtained with ESPRESSO without being limited by wavelength calibration systematics.
URI: http://hdl.handle.net/20.500.12666/629
E-ISSN: 1432-0746
ISSN: 0004-6361
Appears in Collections:(CAB) Artículos



This item is licensed under a Creative Commons License Creative Commons