Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.12666/674
Registro completo de metadatos
Campo DC Valor Idioma
dc.rights.license© Author(s) 2021es
dc.contributor.authorCórdoba Jabonero, C.-
dc.contributor.authorAnsmann, A.-
dc.contributor.authorJiménez, C.-
dc.contributor.authorBaars, H.-
dc.contributor.authorLópez Cayuela, M. A.-
dc.contributor.authorEngelmann, R.-
dc.date.accessioned2022-02-21T11:30:46Z-
dc.date.available2022-02-21T11:30:46Z-
dc.date.issued2021-07-30-
dc.identifier.citationAtmospheric Measurement Techniques 14(7): 5225-5239(2021)es
dc.identifier.otherhttps://amt.copernicus.org/articles/14/5225/2021/-
dc.identifier.urihttp://hdl.handle.net/20.500.12666/674-
dc.descriptionSimultaneous observations of a polarized micro-pulse lidar (P-MPL) system and two reference European Aerosol Research Lidar Network lidars running at the Leipzig site Germany, 51.4∘ N, 12.4∘ E; 125 m a.s.l.) were performed during a comprehensive 2-month field intercomparison campaign in summer 2019. An experimental assessment regarding both the overlap (OVP) correction of the P-MPL signal profiles and the volume linear depolarization ratio (VLDR) analysis, together with its impact on the retrieval of the aerosol optical properties, is achieved; the experimental procedure used is also described. The optimal lidar-specific OVP function is experimentally determined, highlighting that the one delivered by the P-MPL manufacturer cannot be used long. Among the OVP functions examined, the averaged function between those obtained from the comparison of the P-MPL observations with those of the other two reference lidars seems to be the best proxy at both near- and far-field ranges. In addition, the impact of the OVP function on the accuracy of the retrieved profiles of the total particle backscatter coefficient (PBC) and the particle linear depolarization ratio (PLDR) is examined. The VLDR profile is obtained and compared with that derived from the reference lidar, showing that it needs to be corrected by a small offset value with good accuracy. Once P-MPL measurements are optimally (OVP, VLDR) corrected, both the PBC and PLDR profiles can be accurately derived and are in good agreement with reference aerosol retrievals. Overall, as a systematic requirement for lidar systems, an adequate OVP function determination and VLDR testing analysis needs to be performed on a regular basis to correct the P-MPL measurements in order to derive suitable aerosol products. A dust event observed in Leipzig in June 2019 is used for illustration.es
dc.description.sponsorshipThis work was supported by the Spanish Ministry of Science, Innovation and Universities (MCIU) under grants PRX18/00137 (Programa “Salvador de Madariaga”) and CGL2017-90884-REDT (ACTRIS-Spain), the Spanish Ministry of Science and Innovation (MICINN) (grant PID2019-104205GB-C21), and the H2020 programme from the European Union (ACTRIS, GA n. 871115). María-Ángeles López-Cayuela is supported by the INTA predoctoral contract programme. We thank MPLNET for its support even though this study was not part of MPLNET activities. The MPLNET project is funded by the NASA Radiation Sciences Program and Earth Observing System.es
dc.description.sponsorshipThis research has been supported by the Ministerio de Ciencia, Innovación y Universidades (grant nos. PRX18/00137 and CGL2017-90884-REDT), the Ministerio de Ciencia e Innovación (grant no. PID2019-104205GB-C21), and the H2020 European Research Council (grant no. 871115).es
dc.language.isoenges
dc.publisherEuropean Geoscience Union (EGU)es
dc.relationinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/CGL2017-90884-REDT/ES/AEROSOLES, NUBES Y GASES TRAZA ACTRIS‐ESPAÑA/-
dc.relationinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2019-104205GB-C21-
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationales
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectMicro-pulsees
dc.subjectAerosol optical propertieses
dc.titleExperimental assessment of a micro-pulse lidar system in comparison with reference lidar measurements for aerosol optical properties retrievales
dc.typeinfo:eu-repo/semantics/articlees
dc.contributor.orcidCórdoba Jabonero, C. [0000-0003-4859-471X]-
dc.contributor.orcidJiménez, C. [0000-0002-2776-0339]-
dc.contributor.orcidBaars, H. [0000-0002-2316-8960]-
dc.contributor.orcidLópez Cayuela, M. A. [0000-0002-8825-830X]-
dc.contributor.orcidEngelmann, R. [0000-0003-4225-9961]-
dc.identifier.doi10.5194/amt-14-5225-2021-
dc.identifier.e-issn1867-8548-
dc.contributor.funderAgencia Estatal de Investigación (AEI)-
dc.contributor.funderEuropean Research Council (ERC)-
dc.description.peerreviewedPeerreviewes
dc.identifier.funderhttp://dx.doi.org/10.13039/501100011033-
dc.identifier.funderhttp://dx.doi.org/10.13039/501100000781-
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersion-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.type.coarhttp://purl.org/coar/resource_type/c_2df8fbb1-
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/H2020/871115-
Aparece en las colecciones: (Espacio) Artículos



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons