Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/20.500.12666/852
Título : | Dosimeter for The Two Towers in SEOSAT-INGENIO Based on the TMP36 Temperature Sensor |
Autor : | González Guerrero, M. Jiménez, J. J. Hernando, Carlos Álvarez, Maite Guerrero, H. |
Palabras clave : | Data analysis;Dosimetry;Ionizing dose;Radiation effects in devices;Space radiation environment;Total dose effects |
Fecha de publicación : | 14-may-2013 |
Editorial : | Institute of Electrical and Electronics Engineers |
DOI: | 10.1109/TNS.2013.2257848 |
Versión del Editor: | https://ieeexplore.ieee.org/document/6516099 |
Citación : | IEEE Transactions on Nuclear Science 60(4): 2461-2468(2013) |
Resumen : | A dosimeter for space applications is presented. It is based on the ionization damage affecting the TMP36 sensors when they are exposed to external radiation, which produces an increase of their output voltages. This work explains the configuration, sensing mechanism and working modes of this device and reports the results obtained in a gamma radiation test carried out in March 2012. The test results allow us to select the mode of operation that provides the highest response to the TID, as well as the most sensitive devices. The highest sensitivity is above 100 μV/rad. This dosimeter is part of The Two Towers radiation monitor that will fly on board of the SEOSAT-INGENIO satellite. |
URI : | http://hdl.handle.net/20.500.12666/852 |
ISSN : | 0018-2468 1558-1578 |
Aparece en las colecciones: | (Espacio) Artículos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
acceso-restringido.pdf | 221,73 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de Digital.INTA están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.