Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.12666/464
Registro completo de metadatos
Campo DC Valor Idioma
dc.rights.licenseCOPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).-
dc.contributor.authorÁlvarez Herrero, A.-
dc.contributor.authorBelenguer, T.-
dc.contributor.authorPastor, C.-
dc.contributor.authorLópez Heredero, R.-
dc.contributor.authorRamos, G.-
dc.contributor.authorMartínez Pillet, V.-
dc.contributor.authorBonet Navarro, J. A.-
dc.date.accessioned2021-09-27T10:36:51Z-
dc.date.available2021-09-27T10:36:51Z-
dc.date.issued2006-06-14-
dc.identifier.citationProceedings of Space Telescopes and Instrumentation I, Optical, Infrared and Millimeter 6265: 62652G(2006)es
dc.identifier.issn0277-786X-
dc.identifier.otherhttps://www.spiedigitallibrary.org/conference-proceedings-of-spie/6265/62652G/Lithium-niobate-Fabry-Perot-etalons-in-double-pass-configuration-for/10.1117/12.671966.short-
dc.identifier.urihttp://hdl.handle.net/20.500.12666/464-
dc.descriptionCOPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.es
dc.description.abstractThe Imaging MAgnetograph eXperiment, IMaX, is one of the three postfocal instruments of the Sunrise mission. The Sunrise project consists of a stratospheric balloon with a 1 m aperture telescope, which will fly from the Antarctica within the NASA Long Duration Balloon Program. IMaX should work as a diffraction limited imager and it should be capable to carry out polarization measurements and spectroscopic analysis with high resolution (50.000-100.000 range). The spectral resolution required will be achieved by using a LiNbO3 (z-cut) Fabry-Perot etalon in double pass configuration as spectral filter. Up to our knowledge, few works in the literature describe the associated problems of using these devices in an imager instrument (roughness, off-normal incidence, polarization sensitivity...). Because of that, an extensive and detailed analysis of etalon has been carried out. Special attention has been taken in order to determine the wavefront transmission error produced by the imperfections of a real etalon in double pass configuration working in collimated beam. Different theoretical models, numeric simulations and experimental data are analysed and compared obtaining a complete description of the etalon response.es
dc.language.isoenges
dc.publisherSPIE Astronomical Telescopes Instrumentationes
dc.titleLithium niobate Fabry-Perot etalons in double-pass configuration for spectral filtering in the visible imager magnetograph IMaX for the SUNRISE missiones
dc.typeinfo:eu-repo/semantics/articlees
dc.contributor.orcidLópez Heredero, R. [0000-0002-2197-8388]-
dc.contributor.orcidÁlvarez Herrero, A. [0000-0001-9228-3412]-
dc.contributor.orcidMartínez Pillet, V. [0000-0001-7764-6895]-
dc.contributor.orcidPastor, C. [0000-0001-9631-9558]-
dc.identifier.doi10.1117/12.671966-
dc.description.peerreviewedPeerreviewes
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersion-
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccess-
dc.type.coarhttp://purl.org/coar/resource_type/c_6501-
Aparece en las colecciones: (Espacio) Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
acceso-restringido.pdf221,73 kBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de Digital.INTA están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.